Case Study

Riser re-rating options study

Riser re-rating options study

Pages 2 Pages

existing well with a potential shut in pressure of 250 barg through the riser. The riser was protected by a safety integrity level (SIL) 3 rated subsea protection system that had failed a barrier valve leak test. We were asked to determine whether the riser could be re-rated to a higher pressure. This involved reviewing previous assessments, the original design documents and supporting data to identify options for re-rating along with the justications and mitigations for each. The solution We investigated several options for re-routing the existing well, providing an analysis of the benets and challenges of each option. The rst step was to review the available data to determine the maximum pressure rating of each of the components in the system, such as anges and emergency shutdown val