RETROBUOYS INSTALLED ON GERMAN OFFSHORE WINDFARM TO REPLACE FAILING ANODES

RETROBUOYS INSTALLED ON GERMAN OFFSHORE WINDFARM TO REPLACE FAILING ANODES

Pages 1 Pages

RETROBUOYS INSTALLED ON GERMAN OFFSHORE WINDFARM TO REPLACE FAILING ANODES www.acteon.com THE PROBLEM An offshore wind farm in Germany, comprising 80 tripod structures in water depths of 30-40m, was protected by an impressed current cathodic protection system (ICCP) using close mounted anodes. On 33 tripod structures, the existing anodes were beginning to deteriorate and the levels of cathodic protection current was falling and failing to adequately protect the structures submerged steel surfaces. THE SOLUTION MENCK Evaluation Deepwater, an Acteon company, carried out an initial estimate of the cathodic protection (CP) current that would be required to provide adequate levels of CP to the tripod for an extended period and this was found to be approximately 280 A, as a mean current