Case Study
Horseshoe Dam Intake Tower Salt River Project
This study was performed to identify and analyze potential dam safety de? ciencies at the Horseshoe Dam Intake Tower, which was scheduled for modi? cations. The study was performed to evaluate the potential for structural or mechanical failure during the Maximum Credible Earthquake (MCE) which would result in either a loss of reservoir or damage to the structural and mechanical components, rendering them inoperable. The MCE f