Case Study
Barge Loading, Rail Car, & Truck Loading VOC Control System
Barge Loading, Rail Car, & Truck Loading VOC Control System Air Clear provided a Thermal Oxidizer (VOC Control System) to control the emissions from a Barge Loading, Rail Car & Truck Loading for the Oil & Gas Industry Process Design Parameters Average Process Flow (SCFM): 175 (Dilution air is required for upset and high flow conditions) Process Temperature (oF): 60-100 Pollutant (lbs/hr): 0-193 Total Average Heating Value of Pollutants (BTU/#): 21,500 THERMOX Inlet Static Pressure (WC): -1WC Purification Temperature (oF): = 1,500175 SCFM THERMAL OXIDIZER, VOC CONTROL SYSTEM, (DILUTION AIR WAS REQUIRED FOR UPSET AND HIGH FLOW CONDITIONS) VOC DESTRUCTION EFFICIENCY The proposed Thermal Oxidizer is capable of converting 99% of the VOC’s to H 2 O and CO 2 . The