Emissions from eight noodle ovens were causing visible emissions and also oil/grease coating on the roof around the exhaust stacks
Emissions from eight noodle ovens were causing visible emissions and also oil/grease coating on the roof around the exhaust stacks
Case Study Client: Envita for Large Noodle Manufacture, who’s name is confidential Location: South Korea Background: Emissions from eight noodle ovens were causing visible emissions and also oil/grease coating on the roof around the exhaust stacks. Air Clear looked at comparison of two technologies. Regenerative Thermal Oxidizer (RTO) and Fiberbed Mist Collector. The cost advantage was clearly in favor of the Mist Collector, however the end user wanted to see performance as this was the first application of the Mist Collector on a noodle manufacture. The three month Pilot Test demonstrated that the Mist Collector removed greater than 99% of all oil aerosol particulate greater than 0.1 micron and larger. Waste Description: Oil and grease aerosol mist from hot peanut, coconut and veget