Case Study
Net Gas Cl Treaters within a UOP CCR, Oklahoma Refinery - Vari Zeo Replacing Pro Alumina Charge
Case Study – Oklahoma Refinery Recent UOP CCR – Case Study Page 1 of 3 CASE STUDY Net Gas Cl Treaters within a UOP CCR, Oklahoma Refinery Vari Zeo Replacing Pro Alumina Charge This is a Refinery located in Oklahoma with a 1.42 MMSCFH UOP designed CCR. The focus of this study will be the Net Gas Chloride Treater, of which this refinery has one. The following is based on conditions within the CCR during two time periods; a) 23 months of use with alumina material November 2009 until October 2011. b) 6 months of use with CLS Vari Zeo October 2011 until April 2012. For the purpose of this case study, we will evaluate the effects of each material on the CCR, as well as the costs associated with the use of each mater