Case Study

Modular Process Case Studies

Modular Process Case Studies

Modular Process Case Studies 90% CO2 Sequestration from Coal Fired Flue Gas Achieved with Pilot Distillation Column CO2 was removed from flue gas in a two- step distillation process. A pilot-scale distillation system allowed the client to test various system parameters and prove a new CO2 removal technology DISTILLATION SYSTEM CLIENT: Akermin, Inc. INDUSTRY: Post-Combustion CO2 Capture for Electric Utilities KEY ENGINEERING FEATURES: Compact Footprint: 51 feet tall, 39,000 pound distillation pilot plant skid Two packed distillation columns comprised of multiple pipe spools, rated for 120 psig at 266 degrees Fahrenheit with full vacuum Re-boiler used to generate steam for CO2 stripping in the second column Hydrotesting completed for entire system to check for leaks FEA analysis on skid fram