Vibration Eliminated in Gland Steam System using Fisher Valve with Whisper Trim III

Vibration Eliminated in Gland Steam System using Fisher Valve with Whisper Trim III

Pages 2 Pages

For more information: www.Fisher.com POWER Vibration Eliminated in Gland Steam System using Fisher TM Valve with Whisper Trim TM III RESULTS • Noise was reduced and damaging vibration eliminated when a non-Fisher TM valve was replaced by a Fisher EHS valve with Whisper Trim TM III. APPLICATION Superheated steam control in gland steam system CUSTOMER 1,000 Megawatt coal-fired power plant in China CHALLENGE This coal-fired power plant was experiencing a serious vibration problem with a non-Fisher gland steam control valve used to control the supply of superheated steam to the gland steam system. The gland steam system acts as a seal, keeping the process steam in and air out of the steam turbine to optimize its efficiency and prevent corrosion damage. The gland steam control val