Case Study
Utilising Waste Heat From Galvanizing
PUK-WERKE KG FACTORY SCHÖNECKEN Industriestraße 1, 54614 Schönecken, Germany The waste heat from oil ? red galvanising furnaces is used to heat the water for the degreasing bath. The exhaust gas temperature is cooled from 320 °C down to 80 °C. The water in the degreasing bath is heated from 55 °C up to 70 °C. Two exhaust gas heat exchangers with integral fans are used. INDUSTRY UTILISING WASTE HEAT FROM GALVANIZING Heat generator: Galvanizing f