Case Study
Tequila Cuervo-The bacteria love Tequila-over 99.9% BOD removal
PLANT HIGHLIGHTS Client: Tequila Cuervo Wastewater: 32,000 gpd (120 M3/day) with a BOD> 15,000 mg/l from tequila destruction Challenge: Design a treatment system on a very small site to handle combination of sanitary waste- water and tequila liquor with COD over 15,000 mg/l. Solution: Provide a pre-treatment for the high strength wastewater using a moving bed bioreactor (MBBR) and then blend it with sanitary wastewater for activa