Spray Nozzle Test Stand APPLICATION A component manufacturer required a test stand to qualify windshield washer spray nozzles. Nozzles must meet a water flow rate specification of 1000 mLpm (0.26 GPM) with a tolerance of ± 100 mLpm at 18psi as per the car manufacturer. The test stand operator needs an indication of pass or fail. MCMILLAN PRODUCTS UTILIZED 250 Multifunction Display 250-11 Alarm Output Card 101-7 Liquid FLO-SENSOR 100-17T Cable Assembly DESCRIPTION McMillan Multifunction Displays have many features. When combined with the optional Alarm Output Card, they can be used to perform high/low alarm functions. The Model 250 has an internal 12v power supply that provides power to the 101-7 FLO-SENSOR via the 100-17T Cable Assembly. OP