Case Study
Single-Line Bypass Solution Reduces Risk of Failure for a Critical Pressure Control Station
D352713X012/Aug17 For more information: www.Fisher.com GAS TRANSMISSION Single-Line Bypass Solution Reduces Risk of Failure for a Critical Pressure Control Station RESULTS • Reduced risk of downtime, saving up to $3M USD per year • Improved the stability and accuracy of pressure control and valve performance over a wide range of seasonal flows • Reduced valve noise to near background levels • Provided overpressure protection and ensured sustained operation in the event of a failure by using a main- monitor configuration • Completed the project on time and on budget APPLICATION Single-line bypass valves in a pressure-reducing station for a gas transmission pipeline supplying a distribution system CUSTOMER A pressure control station on the border between Canada and the USA CHALLENG