Case Study
Multi-Storey Residential Buildings with Commercial Units and an Underground Parking Garage in Krakow, Poland
Multi-Storey Residential Buildings with Commercial Units and an Underground Parking Garage in Krakow, Poland
Civil and structural design MGM Konstrukcje Inzynierskie s.c. www.mgm-ki.pl Software Dlubal Software Sp. z o.o www.dlubal.pl residential part and 80 cm in the courtyard (with local thickening in the column areas and passageways). The exterior garage walls are rein- forced concrete with a thickness of 25 cm. The underground floor located at the garage level is designed entirely as a monolithic slab with a slab-column system, with deep beams used as columns. Reinforced concrete walls were intro- duced at the entrance area of the garages and work as stiffeners in the vehicle traffic area – staircases and lift cores, as well as separating the technical facilities. The internal reinforced concrete walls are generally 25 cm thick, no less than 20 cm. The thicknesses of the lif