Case Study
Large Flow Rate? Huge Piping
Photo Far Left: View of Open Top Photo Left: Custom Spool once CASESTUDY– LargeFlowRate?HugePiping water has started filling Photo Below: Completed Custom Spool LargeFlowRate?HugePiping Location: Pilbara Mine Site Western Australia The tank construction was an Open p Top TS600 model. The tank had outlet flow -rate requirements of 10,500m3 p/hr; through a 1200NB orifice. We successfully designed, fabricated and installed an anti -vortex outlet with both internal water straightening baffles and a vortex plate to give maximum hydraulic efficiency. Amidst the dusty and dry conditions our crew were able to complete the tank construction within 6 days. Tank Dimensions: 15.75m x 8.81m high Effective capacity: 1,400kL Photo Far Right: Completed TS600 Open Top Tank Photo Right: Attaching exte