Ionizing Wet Scrubber (IWS) Removes Both Acid Gas and Submicron Particulate
Ionizing Wet Scrubber (IWS) Removes Both Acid Gas and Submicron Particulate # 110 Application Liquid Waste Incineration Exhaust Volume 64,400 ACFM Exhaust Temperature 147°F saturated Exhaust Pressure 3.0” W.C. (<1.0 per stage) Contaminant HCl, Cl 2 , HBr Submicron Particulate Removal Efficiency Acid Gases > 99.9% Particulate > 98% (<0.003 gr/ DSCF) Scrubbing Solution Dilute NaOH solution Materials of Construction FRP & Polypropylene