Generator Manufacturer Customer: Generator Manufacturer Application: Diesel transfer from back up tank to day tank Location: UK Equipment supplied 2 Qty 1" Gear pumps mounted on common baseplate for duty/standby operation. Transferring fuel from a bulk tank installed in a basement to a roof mounted day tank. Fluid: Diesel Oil Capacity (Q): 50 l/min Pressure (H): 85 mLC Inlet/Outlet: 1" Casing: GG 25 Cast Iron Gears: GGG 40 Cast Iron Shaft: 1050 Steel, Heat Treated 2.2Kw, 1450RPM 400V/3Ph/50Hz Enquiry This customer required a duplex pump set to transfer diesel fuel from a bulk tank installed in a basement to a roof mounted day tank. The total lift height was 26.5 m with a total pipe route length of approximately 80m. Solution We selected 2 of our 1” Internal Eccentric Gear Pumps complete w