The Solution The damage was being caused by water penetration through the balcony and step surfaces reacting with the steel reinforcement. High pressure power washing to remove contaminants and debris followed by repairs to the surfaces where necessary and then the application of a TorDeck Balcony anti -slip Coating system. The system comprises of a 3 part edge detail and 4 part main walkway system incorporating a fibreglass bridge matting layer. Once the top surfaces were sealed the undersides could be repaired using the Flexcrete Repair system. Spalling concrete and defective concrete is broken out , steel reinforcement cleaned and treated with Flexcrete steel prime 841, a layer of Flexcre te Bond aid 842 applied before the repair using Flexcrete Monomix polymer modified cementiti