PERFORMANCE RESULTS EXAMPLE Tube Size 40 mm ID (1,575”) Tube length 5 m # of Tubes 484 Inspection Time • ½ shift including setup Defects Found • 16 tubes with multiple holes Condenser in milk factory Food & Beverage Industry (Netherlands) Outcome Tubes with holes were plugged and condenser very fast back in operation