Pages 2 Pages

Well Data China - Asia Pacific Location: Oil Producer - Sandstone Well Type: November 2014 Installation Date: Depth: 1700 - 1945m Tendeka was asked to provide a solution that would reduce water cut from oil producers to allow increase in oil production rates and increase field recovery rates. The Challenge Wells producing from the field were typically producing with high water break-through early in their life. The existing wells in the field were completed with stand-alone screens where oil production was declining due to increase in water cut. The length of the well is relatively short and production is minimal (1000m3/d liquid) therefore a challenge for inflow control. Tendeka’s Solution Tendeka’s FloSure Autonomous Inflow Control Device (AICD) provides the ability to choke