Case Study

Float Operated Liqui-Mover Pump

Float Operated Liqui-Mover Pump

Pages 1 Pages

08/10 Challenge A cereal processing food plant experienced problems maintaining consistent temperature in its rotating flaker dryers. The plant uses temperature control valves to regulate the steam pressure to the dryers. When the steam pressure drops below a certain pressure, the dryers flood. To keep the dryers from flooding, the dryer operators open a valve to the floor drain. This method of operation allowed valuable hot condensate to be lost and created safety concerns. Solution Kadant sales and application engineers proposed removing the existing steam traps on each of the dryers and installing a Liqui-Mover pump on each of the 12 dryers. The Liqui-Mover pump uses steam pressure to pump the condensate back to the boiler thereby eliminating the need for conven