Evapco Fin Press Noise Evaluation Summary: The Evapco Fin Press noise evaluation will determine if this industrial machine is in compliance with their hearing conservation program or if corrective measures are necessary. There is concern that the Fin Press operator’s noise exposure may be exceeding the OSHA Actin Level and the OSHA Permissible Exposure Limit. A noise evaluation on the Fin Press provides the noise characteristics of the machine’s noise level. The measurements show the A-weighted sound pressure levels at the operator location peaks around 97 dB(A). The stamping action of the Fin Press is the major component to the noise that produces dominant frequency components at 200 Hz and 630 Hz. The Fin Press noise spreads out in an omni-directional pattern from the distributed noise s