Case Study
Cyclone Tub Resurfacing Saves Over $100K/Year Per Cyclone
Cyclone Tub Resurfacing Saves Over $100K/Year Per Cyclone Challenge Issue Discharge launderer rings below hydrocyclone experienced severe impact abrasion causing ceramic tiles to fail. Goal Replace failing system with a solution able to protect against harsh conditions. Root Cause High-impact, flow-induced, slurry abrasion Solution Preperation Surfaces cleaned with High Press water then mechanically abraded to roughen surfaces to SP11 cleanliness with 2 + mil profile. Application ARC I BX1 was initially applied on all exposed surfaces. After a six-month inspection, the impingment area directly below the discharge cone was upgraded with ARC MX1 based on our recommendation. Results Client Reported ¦ ¦ Unscheduled shutdowns have been reduced 50%. Each shutdown now takes one-thi