Civa modelling of the inspection of a nozzle to domed end weld on a production separator
www.sonomatic.com Case Study Design Project Figure 1: Figure 2: Figure 3: Project: Civa modelling of the inspection of a nozzle to domed end weld on a production separator. Problem: An inspection was required on a production separator in order to give confidence that no flaws were present within a nozzle weld following a dynamic loading event. Sonomatic were approached in order to validate the capability of the inspection approach. Benefits: Analysis of the results determined the likelihood of detection for each of the flaws within the weld and was used to validate the inspection techniques applied to the nozzle. The use of modelling allowed the techniques to be developed rapidly with confidence in capab