Case Study
Black Powder Contamination in LPG Loading Line - Targa Resources
Case Study Black Powder Contamination in LPG Loading Line Targa Resources Houston, 2016 www.BlackPowderSolutions.com P: 1.403.212.1810 E: marketing@blackpowdersolutions.com Problem: Traditional basket strainers designed for high flow LPG loading ship applications are inefficient filtering Black Powder. High levels of Black Powder (30 microns and larger) cause basket screens to plug off flow. The most damaging Black Powder, below