Case Study
API 15000 6A PR2 - Trunnion Ball Valve
Case studies EGC Seal Design Pressure energized Optipak® stem seal set. www.EGCcomponents.com Testing Details and Results Hydrostatic Pressure T est • Media: Water • Temperature: 75°F • Test Details: Pressurize the test fixture to 22,500 psig and dwell for 1 hour. • Results: PASSED. No change in pressure observed. Ambient T emperature Static Test • Media: N2 • Temperature: 75°F • Test Details: Pressurize the fixture to 22,500 psig an