Case Study
Amarinth designs bespoke API 610 VS4 Vertical Sump Pump with integral monitoring of line bearing temperature for GASCO
Amarinth designs bespoke API 610 VS4 Vertical Sump Pump with integral monitoring of line bearing temperature for GASCO
Overheating bearings GASCO had suffered historical operating problems with API 610 VS4 vertical sump pumps due raised temperatures of the line bearings caused by sand ingress from the produced water. To address this hazard, when the company issued the technical specifications for a new water sump project at its Habshan facility in the United Arab Emirates, an updated operating approach included the requirement of a warning system tha