Case Study
ALFA - HRTT applications in leak detection and behind casing channeling
CASE STUDY: Leak detection and reservoir monitoring ALFA-HRTT applications in leak detection and behind casing channeling Challenge ? An operator is facing SAP issues in one of its new gas wells. The well is not yet perforated nor was put on production however they noticed developed annulus pressure. ? The objective is to pinpoint leak sources to plan for future repair intervention and to check whether there is behind casing channeling thru cement. Solution ? A team of GoWell personnel with wide expertise and knowledge regarding well integrity and reservoir monitoring proposed to run ALFA tool (Acoustic Leak Flow Analyzer). The remarkable capabilities of this passive tool logged on stations will aid to identify/monitor fluid flow behind casing at the re