Case Study

Alexandria Motors - 72% energy reduction

Alexandria Motors - 72% energy reduction

Pages 1 Pages

Case Study LED Done Right ® www.energybankinc.com exterior model T ® Alexandria Motors Alexandria, MN EXISTING Two - 1090W HID RETROFIT One - 600W model T project data type qty energy per unit total energy existing HID 32 1090W 34,880W upgrade model T 16 600W 9,600W Total Energy Reduction 25,280 watts 72% energy reduction The Alexandria Motors outdoor showroom was renovated to a modern look and feel when 16 poles with two 1090 watt HID fixtures each were retrofitted with a single 600 watt energybank model T exterior LED fixture each. The result is a huge improvement in both appearance and performance with significant energy and maintenance savings. Street Side 10’ 2.1 FC 4.1 FC Pole Base 0’ 20 FC 24 FC Lot Side 10’ 23 FC 49.5 FC Lot Side 20’ 17 FC 34 FC Lot Side 30’ 10 FC